Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22.003
Filtrar
1.
J Int Soc Prev Community Dent ; 14(1): 43-51, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38559644

RESUMO

Aim: Long-term clinical success on indirect restorations is largely determined by bonding efficiency of the luting agent, with adhesion to dentin being the main challenge. Therefore, aim of this study was to assess the microtensile bond strength when using flowable resin composite, preheated resin composite and dual self-adhesive resin cement as dentin luting agents. Materials and Methods: Occlusal thirds of molar teeth were cut and randomly divided into 3 groups to be cemented: RelyX™U200, Filtek™ Z250 XT- preheated to 70° and Filtek Flow™ Z350XT. They were then thermocycled 5000 times between 5+/-2°C and 55+/-2°C. Subsequently, 10 microbars per group were prepared. The 30 samples were placed in saline solution for 24 hours at room temperature prior to microtensile test. This was performed with a digital universal testing machine at a crosshead speed of 0.5 mm/min. The bond strength values obtained were analyzed in Megapascals (MPa). Measures of central tendency such mean and measures of dispersion such standard deviation were used. In addition, the Kruskall Wallis non-parametric test with Bonferroni post hoc test was applied, considering a significance value of 5% (P < 0.05), with type I error. Results: The dentin microtensile bond strengths of preheated resin composite, flowable resin composite and dual self-adhesive cement were 6.08 ± 0.66 Mpa, 5.25 ± 2.60Mpa and 2.82 ± 1.26Mpa, respectively. In addition, the preheated resin composite exhibited significantly higher microtensile bond strength compared to the dual self-adhesive cement (P < 0.001). While the flowable resin composite showed no significant difference with the dual self-adhesive cement (P = 0.054) and the preheated resin composite (P = 0.329). Conclusions: The microtensile bond strength in dentin was significantly higher when using a preheated resin composite at 70°C as a luting agent compared to dual self-adhesive cement. However, the preheated resin composite showed similar microtensile bond strength compared to the flowable resin composite.

2.
Heliyon ; 10(7): e27714, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38560196

RESUMO

This study examined the effect of traverse speed on the mechanical properties, corrosion-resistance behavior, and microstructure of friction stir-welded A390/10 wt% SiC composites-AA2024 Al alloy joints. The laminar flow of both materials was found to diminish in the stir zone (SZ) when the traverse speed of the tool increased from 40 to 80 mm/min, lowering their mixing rate. Large aspect ratio Si particles are broken by the tool pin-induced applied plastic strain, which turns them into refined equiaxed particles. Their aspect ratio remains unchanged in the SZ, despite their decreasing size. SiC and Si particles progressively come into view when moving from the AA2024 alloy's SZ to the composite workpieces. These changes happen abruptly as traverse speed increases due to the lack of an interfacial layer structure. The advancing side (AS)'s SZ grain size drops from 4.2 ± 0.3 µm to 1.2 ± 0.2 µm as the traverse speed drops from 80 to 40 mm/min. Increased traverse speed from 40 to 80 mm/min will result in a 5.8% decrease in elongation percentage (EP) and 8.4%, 36%, and 10.3% increases in the ultimate tensile strength (UTS), corrosion resistance, and yield strength, respectively.

3.
Acta Stomatol Croat ; 58(1): 30-38, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38562217

RESUMO

Objective: The aim of this study was to compare the light transmission of monowave and polywave-curing devices by a bulk-fill composite containing only camphorquinone as a photoinitiator. Materials and methods: Three light-curing devices were used to cure bulk-fill composite QuiXfil: one monowave (Translux® Wave) and two polywave (VALO Cordless and Bluephase® PowerCure. The NIST-calibrated spectrometer (MARC Resin Calibrator, BlueLight Analytics Inc.) was used to measure the incident and transmitted light through a 2-mm composite specimen over 20 s. Light transmittance was calculated from the ratio of the amount of transmitted and incident light. For data analysis (ANOVA, α = 0.05), total irradiation of the entire spectrum, irradiation with wavelengths of 360-420 nm for the violet spectrum, and 420-540 nm for the blue spectrum were selected. Results: Monowave curing unit Translux® Wave had the lowest light transmission (13.78 ± 0.5%), similar to the violet light transmission of polywave devices (12.02 ± 0.94% and 13.81 ± 1.72% for Valo Cordless and Bluephase PowerCure, respectively). Blue light transmittance (32.15-23.70%) was more than twofold higher than for the wavelengths in the violet region of the spectrum (13.81-12.02%) for the two polywave devices. VALO Cordless showed the highest total and blue light transmission (p<0.001). There was no significant difference in the transmission of the violet part of the spectrum between VALO Cordless and Bluephase® PowerCure (p = 0.465). Conclusion: Within the limitations of this study, we could conclude that polywave curing devices can be used for the polymerization of the bulk-fill composite with camphorquinone as the sole photoinitiator.

4.
Acta Stomatol Croat ; 58(1): 18-29, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38562221

RESUMO

Objectives: To compare three different orthodontic adhesives (Transbond XT Light Cure Adhesive, Heliosit Orthodontic, Fuji Ortho LC) bonded to two types of orthodontic brackets: ceramic brackets (Fascination Roth 0.22) and metallic brackets (Topic Roth 0.22, Dentaurum). Materials and methods: The study was performed on 18 human teeth (6 for each adhesive). The prepared teeth were divided into three groups according to the examination time. Subsequently, they were observed after 1, 2 and 3 weeks following bonding. After the experimental procedure, the teeth samples were cut in half along the longitudinal axis in the vestibulo-oral direction, fixed with conductive carbon cement, placed in a high-vacuum evaporator and then coated with carbon. One half of each sample was observed under a Field-emission gun scanning electron microscope (FEG-SEM Hitachi SU 8030, Japan), while on the second half of the samples qualitative (X-ray line-scans) and semi-quantitative point X-ray energy dispersive analyses (EDX) were performed with Thermo Noran (USA) NSS System 7, equipped with Ultra Dry detector (30 mm2 window). Results: Transbond XT had an ideal bond with the enamel and the bracket base, with rare presence of microgaps and cracks in the enamel. Heliosit Orthodontic demonstrated a better bond relationship with the bracket base than the enamel, whereas in the latter the presence of microgaps in the bond was observed. The microphotographs of Fuji Ortho LC demonstrated many cracks inside the adhesive, and some of them continued to move forward into the enamel surface. Therefore, an impression of a very solid bond relationship with the enamel exists, with cracks being present in the enamel surface and never at the enamel-adhesive interface. Microgaps also appeared at the bracket-adhesive interface. Conclusion: Transbond XT is a highly filled composite resin and is an ideal orthodontic adhesive in each aspect examined, with an ideal enamel-adhesive and bracket-adhesive interface. Heliosit Orthodontic provides better bracket-adhesive interface compared to the enamel. Fuji Ortho LC as a solid resin-modified GIC provides a better enamel-adhesive interface, compared to the bracket base.

5.
Odontology ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38568323

RESUMO

The aim of this study is to investigate the repair bond strength of composite resin following three different surface treatments (bur-grinding, silanization, and Er,Cr:YSGG laser irradiation) using various universal adhesives. A total of 160 resin composite specimens, produced in cylindrical form (6 × 2 mm) with a nanohybrid composite resin within metal molds, were subjected to 5000 cycles of aging in a thermocycler. The aged samples were categorized into four groups based on surface treatments: control, bur, silane, and Er,Cr:YSGG laser. Following surface treatments, the specimens underwent repair using the same resin composite and four different adhesive systems: Tokuyama Universal Bond (TUB), Prime Bond Universal (PBU), Gluma Bond Universal (GBU), and Clearfil SE Bond (CSB). Subsequently, the specimens were subjected to shear forces, and statistical analysis was performed using two-way ANOVA and Tukey tests (p < 0.05). The failure modes were examined using a stereomicroscope, and the surface topography of the roughened resin composite was assessed through scanning electron microscopy (SEM). Results indicated that silane + GBU exhibited the highest shear bond strength (SBS) (15.61 MPa) while control + TUB showed the lowest SBS (7.63 MPa). Silane demonstrated significantly higher SBS values (p ≤ 0.05), with no significant difference observed between bur and laser methods (p = 0.998). It is recommended to include an additional silanization step before applying universal adhesive, as it effectively enhances the bond strength of the repaired composite.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38558337

RESUMO

Flow electrode capacitive deionization (FCDI) is a promising technology for efficiently treating industrial brine with high salt content. However, its desalination performance is currently limited by internal resistance. Achieving an effective FCDI system relies on active electrode materials with high conductivity. This study compares the desalination performances of the widely used flow electrode activated carbon (AC) with more conductive materials, reduced graphene oxide (rGO), and ZnO/rGO composite. Additionally, the lack of particle-to-particle contact in the flow electrode contributes to internal resistance and to address this, a cationic surface-active agent is introduced. This agent forms a stable dispersion, creating a space for enhanced mass loading of the active material. This modification enhances the conductive network and particle contact, reducing the diffusion path and promoting rapid ion transport. With a 5 wt% loading, ZnO/rGO achieved a 73% salt removal efficiency, surpassing AC at 63%. Furthermore, the surfactant-modified ZnO/rGO flow electrode with a 7 wt% loading demonstrated an 81% salt removal efficiency.

7.
J Biomater Appl ; : 8853282241243337, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561006

RESUMO

In this study, we evaluated the use of graphene oxide (GO) mixed with methyl methacrylate gelatin (GelMA) for the construction of a microenvironmental implant to repair bone defects in orthopedic surgery. A scaffold containing a GelMA/GO composite with mesenchymal stem cells (MSCs) was constructed using three-dimensional bioprinting. The survival and osteogenic capacity of MSCs in the composite bioink were evaluated using cell viability and proliferation assays, osteogenesis-related gene expression analysis, and implantation under the skin of nude mice. The printing process had little effect on cell viability. We found that GO enhanced cell proliferation but had no significant effect on cell viability. In vitro experiments suggested that GO promoted material-cell interactions and the expression of osteogenesis-related genes. In vivo experiments showed that GO decreased the degradation time of the material and increased calcium nodule deposition. In contrast to pure GelMA, the addition of GO created a suitable microenvironment to promote the differentiation of loaded exogenous MSCs in vitro and in vivo, providing a basis for the repair of bone defects.

8.
Rheumatol Immunol Res ; 5(1): 34-41, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38571930

RESUMO

In Sjögren's Syndrome (SS), clinical heterogeneity and discordance between disease activity measures and patient experience are key obstacles to effective therapeutic development. Patient reported outcome measures (PROMs) are useful tools for understanding the unmet needs from the patients' perspective and therefore they are key for the development of patient centric healthcare systems. Initial concern about the subjectivity of PROMs has given way to methodological rigour and clear guidance for the development of PROMs. To date, several studies of patient stratification using PROMs have identified similar symptom-based subgroups. There is evidence to suggest that these subgroups may represent different disease endotypes with differing responses to therapeutic interventions. Stratified medicine approaches, alongside sensitive outcome measures, have the potential to improve our understanding of SS pathobiology and therapeutic development. The inclusion of PROMs is important for the success of such approaches. In this review we discuss the opportunities of using PROMs in understanding the pathogenesis of and therapeutic development for SS.

9.
J Pharm Bioallied Sci ; 16(Suppl 1): S690-S694, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595355

RESUMO

Aim: This study intends to evaluate the frequency and causes of replacement for failed amalgam and composite dental restorations. Methodology: A cross-sectional study comprising female patients with failed permanent composite and amalgam restorations aged 15-60 years old was carried out at the dental clinics of Qassim University. Using a self-structured proforma, demographic data and causes for restoration failure were recorded. The effectiveness of the restorations was assessed by using the Ryge criteria after performing clinical and radiographic examinations. The Statistical Package for Social Science was used for the statistical analysis. Results: It is found that 84.6% of the 299 unsuccessful restorations examined were composite, and 15.4% were amalgam. The main reason for dental failure for both amalgam (95.6%) and composite (93.28%) restorations was secondary caries. Failure of amalgam restoration was largely caused by poor marginal adaptation. With varied incidences between amalgam and composite restorations, typical complaints included discomfort, sensitivity, pain, and food impaction with soreness. The main justification for replacement in amalgam restorations was sensitivity. Repair and replacement rates were similar for amalgam, composite, and mandibular/maxillary restorations. Moreover, 21.1% of individuals overall reported no symptoms, with 8.7% in the amalgam group and 23.3% in the composite group with significant differences (χ2 = 34.28, P = 0.001). Conclusion: According to the current study, secondary caries was found to be the main reason for both amalgam and composite restoration failure. The main problems reported were sensitivity, discomfort, and pain with amalgam showing more sensitivity-related failures.

10.
J Pharm Bioallied Sci ; 16(Suppl 1): S427-S430, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595483

RESUMO

Background: Surface roughness and hardness are key factors that influence the clinical performance and durability of denture teeth. Understanding variations in these properties among different denture teeth materials can assist in selecting the most suitable materials for optimal patient outcomes. This study aimed to investigate the surface roughness and hardness of four commonly used denture teeth materials: acrylic resin, composite resin, porcelain, and nanohybrid composite. Materials and Methods: Ten specimens were prepared for each denture teeth material, resulting in a total of 40 specimens. Surface roughness was assessed using a profilometer, and measurements were recorded in micrometers (µm). Hardness was determined using a Vickers hardness tester, and results were expressed as Vickers hardness numbers (VHN). The surface roughness and hardness data were analyzed using appropriate statistical tests (e.g., analysis of variance), with significance set at P < 0.05. Results: The results revealed significant differences in both surface roughness and hardness among the different denture teeth materials (P < 0.05). Acrylic resin exhibited the highest surface roughness (mean ± standard deviation: 3.45 ± 0.78 µm) and the lowest hardness (mean ± standard deviation: 45.6 ± 2.3 VHN). Composite resin demonstrated intermediate values of surface roughness (mean ± standard deviation: 1.87 ± 0.54 µm) and hardness (mean ± standard deviation: 65.2 ± 3.9 VHN). Porcelain demonstrated the smoothest surface (mean ± standard deviation: 0.94 ± 0.28 µm) and the highest hardness (mean ± standard deviation: 78.5 ± 4.1 VHN). Nanohybrid composite displayed surface roughness and hardness values similar to composite resin. Conclusion: This study demonstrated significant variations in surface roughness and hardness among the different denture teeth materials evaluated. Acrylic resin exhibited the roughest surface and lowest hardness, while porcelain demonstrated the smoothest surface and highest hardness. Composite resin and nanohybrid composite exhibited intermediate values. These findings provide valuable insights for prosthodontic practitioners in selecting denture teeth materials based on specific clinical requirements, aiming to achieve optimal aesthetics, reduced plaque accumulation, and improved wear resistance.

11.
J Pharm Bioallied Sci ; 16(Suppl 1): S659-S662, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595523

RESUMO

Aim: To compare the sealing ability of three different materials when used as postendodontic restoration barriers to coronal microleakage in root-filled teeth. Materials and Methods: In the present study, 60 single-rooted mandibular premolars with single canals were selected. After endodontic treatment was done with protaper files, they were divided into three groups of 20 teeth each, which were restored with Zirconomer (Group I), Hi-Dense (Group II), and Surefil composite (Group III), respectively. After storing in artificial saliva for 10 days, all teeth were then immersed in Rhodamine 6G fluorescent dye. Teeth were then sectioned buccolingually in a longitudinal direction. The coronal microleakage was measured in both halves under a fluorescence microscope and images were taken with a digital camera. Data obtained from the study in the form of scoring as per specific criteria was subjected to statistical analysis. Result: Results of the study showed that the minimum amount of coronal microleakage was seen in Group II restored with Hi-Dense followed by Group III restored with Surefil Composite and the maximum amount of coronal microleakage was seen in Group I restored with Zirconomer. Conclusion: On the basis of the results of the present study, it may be concluded that Hi-Dense showed better coronal sealing ability in access cavities. Surefil composite exhibited coronal microleakage less than Zirconomer but more than Hi-Dense.

12.
J Pharm Bioallied Sci ; 16(Suppl 1): S930-S932, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595544

RESUMO

Background: Dental restorations play a crucial role in preserving the structural integrity and function of posterior teeth. However, wear resistance remains a significant concern for these restorations. Materials and Methods: In this RCT, 120 participants with posterior tooth restoration needs were randomly assigned to two groups. Group A received conventional composite restorations, while Group B received NanoFilled Composite restorations. The restorations were placed according to standardized protocols. Wear resistance was assessed using a custom-designed chewing simulator, and the material wear was quantified using a profilometer. Patient-reported outcomes and clinical evaluations were also recorded at regular intervals over a 24-month follow-up period. Results: The wear resistance of the NanoFilled Composite restorations (Group B) was significantly higher than that of the conventional composite restorations (Group A) after 24 months of follow-up (P < 0.05). Profilometer measurements revealed that Group B had an average wear depth of 0.15 mm, while Group A had an average wear depth of 0.25 mm. Patient-reported outcomes indicated higher satisfaction and comfort in Group B. Clinical evaluations also demonstrated that Group B restorations had better retention and marginal integrity. Conclusion: This RCT demonstrates that NanoFilled Composite restorations exhibit superior wear resistance compared to conventional composite restorations when used in posterior teeth.

13.
J Pharm Bioallied Sci ; 16(Suppl 1): S389-S392, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595620

RESUMO

Objective: This study used spectrophotometry to examine how staining beverages affect the color stability of three commercial composite materials (nanohybrid composite (A), bulk fill composite (B), and flowable composite (C)) over time. Materials and Methods: Composite discs were randomly divided into groups. The specimens were kept in coffee, tea, red wine, and cola for 14 days at 37°C in the dark. At baseline, 7 days, and 14 days, spectrophotometers measured color. Calculated and analyzed color differences (E). Results: Staining beverages changed the color of all composites. Composite material A had the best color stability, whereas material C stained beverages the most. Red wine and coffee discolored composites most. Discoloration increased over the 14-day immersion period. Conclusion: Composite materials with better color stability were material A. Red wine and coffee discolored composites most. When choosing restorative materials, dentists should consider composite materials' color stability for long-lasting, visually acceptable results.

14.
Heliyon ; 10(7): e28913, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38596064

RESUMO

Magnesium phosphate cement (MPC) is a high-performance repairing material suitable for the interfacial disease of slab track. In this study, the early properties of MPC were optimized using central composite design (CCD) approach based on response surface methodology (RSM). Three factors with five levels and three responses were considered. The significance of the factors and their interactions were verified by using analysis of variance (ANOVA). The result show that the mass ratio of water-to-binder (W/b) affects fluidity, while the mass ratio of magnesia-to-phosphate (M/P) and borax-to-magnesia (B/M) impact the setting time of MPC. Higher W/b results in higher fluidity, while an increase in M/P reduces the setting time by increasing the neutralization reaction. Borax addition retards the reaction, prolonging the setting time. The three factors significantly affect the early compressive strength of MPC. At M/P = 3.5, the interweaving of MgO and K-struvite (MKP) forms a dense network structure, enhancing the strength. Borax and W/b interact to affect compressive strength, with borax retarding MKP crystal growth and higher W/b reducing compactness. Combined with microscopic property test, the strength generation mechanism of MPC with optimized mixing ratio was revealed, And the feasibility of field application of MPC was verified by strength test.

15.
Nano Lett ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598773

RESUMO

The practical application of microsized anodes is hindered by severe volume changes and fast capacity fading. Herein, we propose a gradient composite strategy and fabricate a silicon suboxide-based composite anode (d-SiO@SiOx/C@C) consisting of a disproportionated microsized SiO inner core, a homogeneous composite SiOx/C interlayer (x ≈ 1.5), and a highly graphitized carbon outer layer. The robust SiOx/C interlayer can realize a gradient abatement of stress and simultaneously connect the inner SiO core and carbon outer layer through covalent bonds. As a result, d-SiO@SiOx/C@C delivers a specific capacity of 1023 mAh/g after 300 cycles at 1 A/g with a retention of >90% and an average Coulombic efficiency of >99.7%. A full cell assembled with a LiNi0.8Co0.15Al0.05O2 cathode displays a remarkable specific energy density of 569 Wh/kg based on total active materials as well as excellent cycling stability. Our strategy provides a promising alternative for designing structurally and electrochemically stable microsized anodes with high capacity.

16.
Am J Obstet Gynecol ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599476

RESUMO

BACKGROUND: Standardization of procedures improves outcomes. Though systematic reviews have summarized the evidence-based steps (EBS) of cesarean delivery (CD), their bundled implementation has not been investigated. OBJECTIVE: In this pre- and post-implementation trial, we sought to ascertain if bundled EBS of CD, compared to surgeon's preference, improves outcomes. STUDY DESIGN: A StaRI (Standards for Reporting Implementation Studies) compliant, multi-center pre- and post-implementation trial at 4 teaching hospitals was conducted. The pre-implementation period consisted of CD done based on the physicians' preferences for 3 months; educational intervention (e.g., didactics, badge cards, posters, video) occurred at the 4th month. CDs in post-implementation period employed the bundled EBS. A pre-planned 10% randomized audit of both groups assessed adherence and uptake of EBS. The primary outcome was a composite maternal morbidity (CMM), which included estimated blood loss > 1,000 mL, blood transfusion, endometritis, post-partum fever, wound complications, sepsis, thrombosis, ICU admission, hysterectomy, or death. The secondary outcome was a composite neonatal morbidity (CNM) and some of its components were 5-min Apgar score < 7, positive pressure oxygen use, hypoglycemia, or sepsis. A priori Bayesian sample size calculation indicated 700 CD in each group was needed to demonstrate 20% relative reduction (from 15% to 12%) of CMM with 75% certainty. Bayesian logistic regression with neutral priors was used to calculate likelihood of net-improvement in adjusted relative risk (aRR) with 95% credible intervals (CrI). RESULTS: A total of 1,425 consecutive CD (721 in pre- and 704 in post-implementation group) were examined. Audited data indicated that the baseline EBS utilization rate during the pre-implementation period was 79%; after the implementation bundled EBS of CD the audited adherence was 89%-an uptake of 10.0% of the EBS. In four aspects, the maternal characteristics differed significantly in the pre- and post-implementation periods: race/ethnicity, hypertensive disorder, and the relative contribution of the 4 centers to the cohorts and the gestational age at delivery, but the indications for CD and whether its duration was < versus > 60 min did not. The rates of CMM in the pre- and post-implementation groups were 26% and 22%, respectively (aRR, 0.88; 95% CrI, 0.73-1.04), with a 94 % Bayesian probability of a reduction in CMM. The CNM occurred in 37% of the pre- and in 41% of the post-implementation group (aRR, 1.12; 95% CrI 0.98-1.39), with a 95% Bayesian probability of worsening in CNM. When CMM were segregated by preterm (<37 wks) and term (> 37 weeks) CD, the improvement in maternal outcomes persisted; when CNM were segregated by gestational age subgroupsthe potential for worsening neonatal outcomes persisted as well. CONCLUSIONS: Standardization of the evidence-based bundled steps of cesarean delivery resulted in a modest reduction of the composite maternal outcome; however, a paradoxical increase in neonatal composite morbidity was noted. Although individual evidence-based steps may be of value, while awaiting additional intervention trials a formal bundling of such steps is currently not recommended.

17.
Small ; : e2401152, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38593320

RESUMO

Bacterial infections and inflammation progression yield huge trouble for the management of serious skin wounds and burns. However, some hydrogel dressing exhibit poor wound-healing capabilities. Additionally, little information is given on the molecular theory of hydrogel gelation mechanisms and drug release performance from drug-polymer network in the water environment. Herein, cationic guar gum (CG) is first mixed with dipotassium glycyrrhizinate (DG), and then crosslinked Cu2+ to strengthen the mechanical strength followed by encapsulating mussel adhesive protein (MAP) as composite dressings. Intriguingly, CG-Cu2+ 0.5-DG10 possessed proper rheological properties and mechanical strength predominantly driven by strong CG-H2O-Cu2+ and Cu2+-CG hydrogen bonding interaction. Weak DG-CG hydrogen bonding only controlled DG release in the initial 4 h, while strong hydrogen bonding is the main force regulating the sustained release of Cu2+ within 48 h. The incorporation of MAP further loosened the tight crosslinking of CG-Cu2+ 0.5-DG10. The screened CG-Cu2+ 0.5-DG10/MAP possessed excellent self-healing, injectability, antibacterial, anti-inflammatory, cell proliferation-promotion activities with high biocompatibility. Therefore, CG-Cu2+ 0.5-DG10/MAP hydrogel expedited wound closure on S. aureus-infected full-thickness skin wound model and lowered necrosis progression to the unburned interspaces on a rat burn model. The results highlight the promising translational potential of Cu2+-inspired hydrogels for the management of burns and infected wounds.

18.
Artigo em Inglês | MEDLINE | ID: mdl-38598173

RESUMO

Motivated by the surging demand for low-temperature waste heat harvesting, materials with both prominent thermoelectric and good mechanical properties are preferred in practical applications. In this present work, the composite exploration of Te-doped Mg3.2Bi1.5Sb0.5-x vol % nanosized SiC (x = 0, 0.05, 0.1, 0.2, and 0.5) was carried out, where nanosized SiC is physically dispersed in the matrix in the form of a second phase. SiC second phase compositing further optimized the matrix carrier concentration, resulting in a higher power factor in the service temperature range (the highest value from 28.9 to 31.7 µW cm-1 K-2), and the (ZT)ave from 0.91 to 0.96 compared with the matrix sample. In addition, the SiC second phase effectively enhanced the mechanical properties of composite materials, including flexural strength, microhardness, and modulus. Because of the simultaneous optimization of thermoelectric and mechanical properties, the overall performance of Te-doped Mg3.2Bi1.5Sb0.5-0.05 vol % SiC composite is leveraged to meet special requirements of power generation. It is expected that the addition of SiC should be broadly applicable to address the physical performance in other thermoelectric systems.

19.
Microsc Res Tech ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38590279

RESUMO

This study displays the effect of reduced graphene oxide (rGO) nanofiller and polystyrene-b-poly(ethylene-ran-butylene)-b-polystyrene-grafted maleic anhydride (SEBS-g-MA) on the optical, thermal, and mechanical features of expanded polystyrene (EPS). First, the thin films of pristine EPS and composites were prepared using solution cast method. The prepared films were subjected to fourier-transform infrared (FTIR), SEM, UV-visible spectrophotometer, thermogravimetric analysis/differential scanning calorimetry, and universal testing machine for structural, morphological, optical, thermal, and mechanical characterizations. Optical study revealed a significant increase in refractive index and absorption of composites than EPS. Indirect band-gap energy of EPS (~4.08 eV) was reduced to ~1.61 eV for rGO composite and ~ 2.23 eV for composite composed of rGO and SEBS-g-MA. Thermal analyses presented improvement in characterization temperatures such as T10, T50, Tp, Tm, and Tg of composites, which ultimately lead to the thermal stability of prepared composites than pristine EPS. Stress-strain curves displayed higher yield strength (46.62 MPa), Young's modulus (96.29 MPa), and strain at break (0.54%) for EPS+rGO composite than pure EPS having stress at break (1.01 MPa), Young's modulus (12.44 MPa), and strain at break (0.08%). Moreover, ductility with relatively higher strain at break (0.61%) and lower Young's modulus (79.32 MPa) and yield strength (32.98 MPa) was noticed in EPS+rGO+SEBS-g-MA composite than EPS+rGO composite film. Morphological analysis revealed a change in globular morphology of EPS and inhomogeneous dispersion of rGO in EPS to homogeneously dispersed rGO in EPS matrix without globules owing to the addition of SEBS-g-MA. The increase in compatibility of EPS and rGO due to SEBS-g-MA was also observed in FTIR spectra. RESEARCH HIGHLIGHTS: Here, the solution casting approach was used to create the composite film of EPS and rGO with globules of various sizes. After adding SEBS-g-MA, the shape altered to globular free films exhibiting homogenous dispersion of rGO in EPS matrix. An optical investigation showed that composite materials had a significantly higher refractive index and absorption than EPS. The optical, thermal, and mechanical investigations suggest that the produced composites may be a great substitute for virgin EPS, allowing for a wider range of applications.

20.
Multivariate Behav Res ; : 1-16, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38591183

RESUMO

Regression component analysis (RCA) replaces the factors in a factor analysis model with weighted composites of the model's observed variables. The weight matrix may be calculated from the factor model's parameter estimates. Thus, RCA parameter estimates can be obtained using factor model software, but RCA composites have determinate scores, rather than the indeterminate scores of factors. Analytically, RCA equates to modeling with "regression method" factor scores, except that, while those scores will be inconsistent with the original factor model, they are strictly consistent with the RCA model. When the original factor model is strictly correct in the population and the composites in RCA are standardized, RCA parameter estimates replicate those from regression-weighted forms of partial least squares (PLS) path modeling and generalized structured component analysis (GSCA)-affirming that those methods also equate to modeling with regression method factor scores under the same conditions. Parallel measurement allows RCA to replicate both correlation weight and regression weight versions of PLS and GSCA. These results suggest that RCA and regression-weighted forms of PLS and GSCA are all consistent approaches for modeling data that conforms to a factor model. All analytical methods are described using one consistent symbol palette. Complete R syntax is provided.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...